4.16i/18i DATA SERVER FUNCTIONS IV. OPERATION B-63644EN/02
- 192 -
4.11 MAINTENANCE OF DATA SERVER SCREEN
The Maintenance of Data Server screen is used to format (initialize) a
Fast data server built-in ATA card, check for ATA card errors, switch
between data server modes, and display the error examination data.
Display items
•
••
• STORAGE MODE, BUFFER MODE, and FTP MODE
Display the current data server modes.
•
••
• EMPTY COUNTER
Displays the number of times that the data buffer becomes empty
during transfer of the NC program from the Fast data server to the CNC.
This item is initialized to 0 at power-on. After being initialized, the
item is counted when the conditions are satisfied. When DNC
operation or DNC operation by a subprogram call (M198) is being
executed, this item may be counted up. This indicates that the data
supply from the Fast data server to the CNC is insufficient.
•
••
• TOTAL SIZE
Indicates the total number of bytes when a single NC program is
transferred from the Fast data server to the CNC.
•
••
• READ POINTER and WRITE POINTER
Pointer used to manage the internal buffer for supplying the NC
program between the Fast data server and CNC.