B–63523EN/03
3. INSTALLATION
29
The peripheral units and the control unit have been designed on the
assumption that they are housed in closed cabinets. In this manual
“cabinet” refers to the following:
D Cabinet manufactured by the machine tool builder for housing the
control unit or peripheral units;
D Operation pendant, manufactured by the machine tool builder, for
housing the control unit or operator’s panel.
D Equivalent to the above.
The environmental conditions when installing these cabinets shall
conform to the following table. Section 3.3 describes the installation and
design conditions of a cabinet satisfying these conditions.
Condition
LCD–
mounted
type control
unit and dis-
play unit
(except unit
with data
server
function)
Stand–alone
type control
unit
LCD–mounted
type control
unit with PC
and data server
functions
Ambient
Operating 0°C to 58°C 0°C to 55°C 5°C to 53°C
Tempera-
ture
Storage,
Transport
–20°C to 60°C
Normal
75%RH or less, no con-
densation
10% to 75%RH,
no condensation
Humidity
Short period
(less than 1
month)
95%RH or less, no con-
densation
10% to 90%RH,
no condensation
Operating 0.5 G or less
Vibration
Non–operat-
ing
1.0 G or less
Meters
Operating Up to 1000 m Up to 1000 m
above sea
level
Non–operat-
ing
Up to 12000 m Up to 12000 m
Environ-
ment
Normal machine shop environment
(The environment must be considered if the cabinets are in a loca-
tion where the density of dust, coolant, and/or organic solvent is
relatively high.)
3.1
ENVIRONMENTAL
REQUIREMENTS
OUTSIDE THE
CABINET