B–63522EN/02
27. DISPLAYING AND SETTING DATA
NC FUNCTION
347
The following data are displayed. 7 soft keys can display maximum 640
characters (40 × 16 lines) and 12 soft keys can display maximum 2080
(80 × 26 lines).
The status of the control unit is indicated on the screen. Statuses include
the state when an alarm is being activated or when the system is in the edit
mode. The status line is displayed right above the soft key line.
EDIT STOP MTN FIN ALM hh:mm:ss HEAD1
––EMG––
OUTPUT
Status
line
Soft key
line
Operation mode (MDI, MEM, RMT, EDIT, HND, TJOG, THND,
INC, or REF)
Status of automatic operation (STOP, HOLD, STRT, or ****)
***** : Reset
STOP : Automatic operation is in a stopped state.
HOLD : Automatic operation is in a halt state.
STRT : Automatic operation has been started.
Axis movement/dwell (MTN, DWL, or ***)
FIN wait state (FIN or ***)
Emergency stop (--EMG--) (displayed above in 3 and 4)
Alarm status (ALM, WNG, or ***)
Clock (hh:mm:ss)
Name of the path currently selected (only at 2–path control)
NOTE
The name of a path can be specified by the corresponding
parameter with a string of up to seven characters. The characters
may be numbers, letters, katakana characters, or symbols.
Status display such as program editing (INPUT, OUTPUT, SRCH,
EDIT, LSK, or RSTR)
( and are displayed in the same column. When a program is
being edited, is displayed.)
Data input via the address keys or the numerical keys are displayed at the
left lower part of the screen.
Program number, sequence number is displayed on the right upper part
of the screen.
Alarm number and its contents are displayed briefly.
27.1
DISPLAY
Explanations
D Indication of statuses
and tool post names
D Key input display
D Program number,
sequence number
display
D Alarm display