B–63522EN/02
27. DISPLAYING AND SETTING DATA
NC FUNCTION
383
On the Ethernet parameter setting screen, set the parameters for operating
the FTP file transfer function.
Display
1 Place the CNC in the MDI mode.
2 Press the function key
SYSTEM
.
3 Press the continuous menu key at the right end of the soft key display.
4 Press the [ETHPRM] soft key. The Ethernet parameter setting screen
appears. The Ethernet functions currently available are displayed.
The upper row displays the usable embedded Ethernet function
device.
The embedded port or PCMCIA card is displayed.
The lower row displays the usable Ethernet option boards. When no
option board is installed, no information is displayed.
5 By pressing the [EMBEDD] soft key, the parameters for the
embedded Ethernet port can be set.
By pressing the [PCMCIA] soft key, the parameters for the PCMCIA
Ethernet card can be set.
NOTE
The parameters for the embedded Ethernet port and the
parameters for the PCMCIA Ethernet card are independent
of each other.
27.24.3
FTP File Transfer
Parameter Setting
Screen
Procedure