B–63522EN/02
27. DISPLAYING AND SETTING DATA
NC FUNCTION
381
Display item and setting items
The item related to the embedded Ethernet function is displayed.
Item Description
MAC ADDRESS Embedded Ethernet MAC address
Set the TCP/IP–related items of the embedded Ethernet.
Item Description
IP ADDRESS Specify the IP address of the embedded Ethernet.
(Example of specification format: ”192.168.1.1”)
SUBNET MASK Specify a mask address for the IP addresses of the net-
work.
(Example of specification format: ”255.255.255.0”)
ROUTER IP
ADDRESS
Specify the IP address of the router.
Specify this item when the network contains a router.
(Example of specification format: ”192.168.1.254”)
Set the items related to the FOCAS1/Ethernet function.
Item Description
PORT NUMBER
(TCP)
Specify a port number to be used with the FOCAS1/Ether-
net function. The valid input range is 5001 to 65535.
When using a port number for the DNC1/Ethernet func-
tion, refer to ”FANUC Personal Computer FA System Win-
dows NT Version OPERATOR’S MANUAL (B–75044EN)”.
PORT NUMBER
(UDP)
Specify this item when using the DNC1/Ethernet function.
Specify a UDP port number for transmitting UDP broad-
cast data.
The valid input range is 5001 to 65535.
For details, refer to ”FANUC Personal Computer FA Sys-
tem Windows NT Version OPERATOR’S MANUAL
(B–75044EN)”.
Set 0 when using the FOCAS1/Ethernet function or when
transmitting no UDP broadcast data.
TIME INTERVAL
(NOTE 1)
Specify this item when using the DNC1/Ethernet function.
Specify a time interval at which UDP broadcast data spe-
cified above with a UDP port number is transmitted.
The unit is 10 ms. The valid input range is 10 to 65535.
This means that a value less than 100 ms cannot be spe-
cified.
Set 0 when using the FOCAS1/Ethernet function or when
transmitting no UDP broadcast data.
Example)
100: Broadcast data is transmitted at intervals of one se-
cond [1000 ms] (= 100 10).
Display item related to
the embedded Ethernet
function
Embedded Ethernet
TCP/IP setting items
FOCAS1/Ethernet setting
items