The 200V AC Connection to the Spindle Amplifiers
Note
Before you continue, remember that this following connection is only made
between the power supply module and connecting spindle amplifier modules.
The servo amplifier does not require this connection.
1
.
T
he cable LX660-2077-T202/L… connects the 200V AC power
between the power supply module and the first spindle
amplifier
2
.
Connect the 3-pin connector on one end of the cable to the connector labeled
CX1B
on
the power supply module.
3
.
Connect the other end of the cable to the connector labeled
CX1A
on the first spindle
amplifier module.
4
.
To connect a second spindle module, just connect
CX1B
from the first amplifier to
CX1A
on the second amplifier.
The Bus Bar Connection
The bus bars on connectors
L+
and
L-
make up the connection labeled
TB1
on Figure 1-8.
1
.
Find the bus bar which connects power between the
modules. The part for this piece will depend upon the
specifications of your setup.
2
.
Using one bar, connect the terminal screw labeled
L+
on the power supply module to
the terminal screw labeled
L+
on the first amplifier module. With the other bar,
connect the
L-
terminals on the two modules.
3. When adding on more amplifiers, just use two more bus bars to connect adjacent