B-63003EN-2/01 Chapter 1 Assembling the 16i/18i/21i 1 - 19
1
Connecting the Motor Encoder to the Servo Amplifier
To connect the motor encoder to the servo amplifier, follow this procedure:
1
.
Remove the plastic protective cap from the connector on
the motor and locate the cable for your motor. Look up
your encoder cable part # on the table below
Table 1 - 2. Motor encoder feedback cables
Usage GE Fanuc Severe Duty Cable
A1/3000, A2/2000,
A3/3000AM2/2000, AM2.5/3000,
SVM, SVU
LX660-4077-T264/L3R003 3m
LX660-4077-T264/L4R003 4m
LX660-4077-T264/L5R003 5m
LX660-4077-T264/L6R003 6m
LX660-4077-T264/L7R003 7m
LX660-4077-T264/L8R003 8m
LX660-4077-T264/L10R03 10m
LX660-4077-T264/L12R03 12m
LX660-4077-T264/L14R03 14m
A3/3000 – A150/2000,
AM, AL, AC, HV Servo Motors
SVM
With straight Motor connector:
LX660-4077-T208/L3R003 3m
LX660-4077-T208/L4R003 4m
LX660-4077-T208/L5R003 5m
LX660-4077-T208/L6R003 6m
LX660-4077-T208/L7R003 7m
LX660-4077-T208/L8R003 8m
LX660-4077-T208/L10R03 10m
LX660-4077-T208/L12R03 12m
LX660-4077-T208/L14R03 14m
Or with elbow type motor
connector::
LX660-4077-T209/L3R003 3m
LX660-4077-T209/L4R003 4m
LX660-4077-T209/L5R003 5m
LX660-4077-T209/L6R003 6m
LX660-4077-T209/L7R003 7m
LX660-4077-T209/L8R003 8m
LX660-4077-T209/L10R03 10m
LX660-4077-T209/L12R03 12m
LX660-4077-T209/L14R03 14m
2
.
The cable has two distinct connectors. Plug one end into the connector labeled
ENC1
JF1
on the face of the amplifier module (for the 2nd motor, use
ENC2 JF2
and so on).
3
.
The other end of the cable is configured so that it can only be attached to one of the
two circular connectors on the motor. Go ahead and plug this side in too.
Connecting Motor Power to the Servo Amplifier