5.INSTALLATION B-65282EN/05
- 100 -
5.3.3 Others
Cable length
If a cable is longer than required, a loss of power increases, and the
signal line becomes likelier to be affected by noise. Use each cable of
the minimum required length.
Use of shield cables
• Satisfying the requirements of the EMC Directives
To satisfy the requirements of the EMC Directives enforced in
Europe, it is recommended that a shield cable be used as a power
cable and a double-shield cable be used as a signal cable. If it is
difficult to use a shield cable, it is recommended that a conduit
having an electromagnetic shielding effect be used.
• Protection against noise
Noise generated from the shielded wire of a power shield cable
may affect signals via the shielded wire of a signal cable. For
this reason, separate the ground of the shielded wire of a power
cable from that of the shielded wire of a signal cable. Use
different ground clamping plates (ground plates) for power
cables and signal cables to improve safety.