3.ORDERING INFORMATION B-65282EN/05
- 64 -
For PSM-HV
PSM name
Circuit
breaker 1
Circuit
breaker 2
Circuit
breaker 3
Magnetic
contactor
Remarks
PSM-11HVi
20A 20A
PSM-18HVi
45A 30A
PSM-30HVi
75A 55A
PSM-45HVi
125A 70A
PSM-75HVi
200A 120A
PSM-100HVi
250A
3A 3A
140A
NOTE
1 For the installation positions of the circuit breakers
and magnetic contactor, see Section 1.2.
2 Set the rated voltage of circuit breakers 1 and 2
according to the power supply voltage.
3 The current and voltage of the operation coil of the
magnetic contactor must be within the rating of the
internal contact [CX3 (MCC)] of the PSM.
For details, see Subsection 9.3.1.5.
Recommended parts
Parts manufactured by Fuji Electric Co., Ltd.
PSM name
Circuit
breaker 1
Circuit
breaker 2
Circuit
breaker 3
Magnetic
contactor
PSMR-3i
EA53B/30 SC-5-1
PSMR-5.5i
PSM-5.5i
EA103B/50 SC-1N
PSM-11i
EA103B/60 SC-2N
PSM-15i
EA103B/75 SC-2SN
PSM-26i
EA203B/150 SC-4N
PSM-30i
EA203B/150 SC-5N
PSM-37i
EA203B/175 SC-7N
PSM-55i
EA203B/250
EA33/5 -
SC-8N
PSM-11HVi
EA53B/30 SC-5-1
PSM-18HVi
EA103B/50 SC-1N
PSM-30HVi
EA103B/75 SC-2SN
PSM-45HVi
EA203B/125 SC-4N
PSM-75HVi
EA203B/200 SC-7N
PSM-100HVi
EA203B/250
EA33/3 EA33/3
SC-8N
NOTE
For details, see the brochures available from Fuji
Electric Co., Ltd. Note that the specification of the
coil voltage of a magnetic contactor may differ
depending on the supply voltage and frequency
used.