B-65282EN/05 9.CONNECTION
- 207 -
- Incorporating built-in batteries in each SVM
(Models SVM1-360i, SVM1-180HVi, and SVM1-360HVi)
SVM SVM
Battery case
A06B-6114-K501
Battery case
A06B-6114-K501
Battery
A06B-6073-K001
CX5X
Battery
A06B-6073-K001
CX5X
- Using the built-in battery (A06B-6073-K001) requires the
battery case (A06B-6114-K501).
WARNING
1 When using the built-in battery (A06B-6073-K001),
never connect the BATL(B3) of the connector
CXA2A/CXA2B.
Otherwise, a short-circuit will occur between the
output voltages of different SVM batteries, possibly
resulting in the batteries becoming very hot, which
is dangerous.
2 Do not connect more than one battery to the same
BATL(B3) line.
Otherwise, a short-circuit will occur between the
output voltages of different batteries, possibly
resulting in the batteries becoming very hot, which
is dangerous.