B-65282EN/05 9.CONNECTION
- 195 -
SVM1-360i, SVM1-180HVi, and SVM1-360HVi
Motor
U (U2)
V (V2)
W (W2)
G
SVM
DYNAMIC BRAKE MODULE
Note 1
TB2(U)
TB2(V)
TB2(W)
TB2( )
Flange ( )
Note 2
Flange ( )
Note 3
Note 4
Note 5
NOTE
1 When the α(HV)i series SVM is used, always mount
the motor flange on a cabinet (machine) connected
to the system ground. It may be difficult to connect
the motor flange to a cabinet (machine) connected
to the system ground. In this case, connect the
motor flange and frame ground (ground plate of the
cabinet) using a cable at least 1.25 mm
2
thick. The
cable must be separated from the power lines as
much as possible.
2 Size of screw for motor power line TB2(U), TB2(V),
and TB2(W)
- For SVM1-360i, SVM1-180HVi : M6
- For SVM1-360HVi : M10
3 Connection for motor ground lead
- For SVM1-360i, SVM1-180HVi :
Connection to TB2(G) (M6)
- For SVM1-360HVi : Connection to flange (M6)
4 Size of screws for connection between flange and
ground
- For SVM1-360i, SVM1-180HVi : M5
- For SVM1-360HVi : M6
5 In single-motor twin-amplifier (SMTA) control (in
which one motor is driven by two SVMs), connect
motor power lines U, V, W, and G to the first SVM
and motor power lines U2, V2, W2, and G to the
second SVM.