No.
6/10
Page
FANUC LTD
DESCRIPTION DESIGN DATE
EDIT
Prevention of Gravity Axis Drop
at Power Failure
in αi series servo system
B-65282EN/05-03
Add newly S.Hanyu 04.11.22 01
4. How to keep the excitation of the gravity axis motor
The following condition is required to keep the excitation of the gravity axis after power
failure.
(1) Keep the control power supply of NC and amplifiers.
(2) Set the parameters that enable the brake control function.
4-1. The time to keep the control power supply
It is necessary to keep the control power supply of NC and amplifiers for more than “operate
time of brake”.
The time to keep the control power supply
24V
Operate time of brake
Make
Brake is effective
Power failure
Input power voltage
Status of brake
Break
Contact of relay
24V
×
90% = 21.6V
Control power
supply for NC
and amplifiers
Note) Refer to Section3 about ”Operate time of brake”.
(1) Control power supply for NC
See the specification of the external power supply equipment that supplies the control
power 24V to NC. The time to keep the external power supply equipment depends on the
load rate (the rate of the load current to the rated current of the power supply equipment).
The smaller the load rate is, the time to keep the power supply equipment after power
failure becomes longer. So it is effective to use the power supply equipment whose rated
current is somewhat bigger than the load current to extend the time to keep the power
supply equipment.
(2) Control power supply for amplifiers
The time to keep the control power supply for amplifiers depends on the number of SPM
and SVM connected to PSM. It is possible to calculate the time to keep the control power
supply for amplifiers roughly from the table2. The constant “N” on the table 2 is the total
of the constant “n” for SPM and SVM connected to PSM.
Example: In case that the following SPM and SVMs are connected to one PSM.
SPM-22i : 1 unit
/ SVM1-360i :1 unit / SVM1-160i : 1 unit / SVM2-80/80i : 1 unit
(From table1) n=1 n=1.5 n=1 n=1.5
N = 1×1unit
+ 1.5×1unit + 1×1unit + 1.5×1unit = 5 --- 40msec (From table2)