B-65282EN/05 APPENDIX B.CABLES
- 309 -
B.3 COMPOSITE 10-CORE CABLE
Specifications
Item Unit Specifications
Product No. – A66L-0001-0482
Manufacturer – Hitachi Electric Cable Co., Ltd.
Rating – 80°C, 30V
Conductor, braid-shielded wire,
drain wire
– Strand wire of tinned annealed copper (JIS C3152)
Insulator – Heat-resistant vinyl
Material
Sheath – Oilproof, heat-resistant vinyl
Number of wires (wire nos.) Cores 2 8 (four pairs)
Size mm
2
0.3 0.2
Structure
Conductors
/mm
60/0.08 40/0.08
Conductor
Conductors mm 0.72 0.58
Standard thickness mm 0.25 0.2
Insulator
Outside diameter mm 1.22 0.98
Outside diameter mm – 1.96
Twisted pair
Pitch (approx.) mm –
Lay diameter mm 5.0
Size mm
2
0.15
Structure Wires/mm 30/0.08Drain wire
Outside diameter mm 0.51
Element wire diameter mm 0.12
Thickness mm 0.3
Braid density % 85 or more
Shield braid
Outside diameter (approx.) mm 5.7
Color – Black
Standard thickness mm 0.65
Standard outside diameter
(approx.)
mm 7.0
Sheath
Outside diameter allowance mm 6.5 to 8.0 (Note)
Standard length m 200
Packing method – Bundle
Resistance of conductor (at
20°C) (wire nos.)
Ω/km 69.5 or less 109 or less
Insulation resistance (20°C) MΩ -km 15 or more
Electrical
performance
Dielectric strength (AC) – 500VAC for 5 minutes
Flame resistance – Shall pass flame resistance test VW-1 of UL standards.
NOTE
The maximum outside diameter applies to portions
other than the drain wire.