9.SETTING AND ADJUSTMENT B-70255EN/01
- 130 -
Code Name of function
Initial
value
Setting
value
Remarks
A101 01 start 0.00Hz 0.00Hz
A102 01 end 0.00Hz 0.00Hz
0.00 to 1500
A103 01 start ratio 20% 20%
A104 01 end ratio 100% 100%
0 to 100
A105 01 start selection 01 01
00: External start frequency, 01: 0 Hz
A111 02 start 0.00Hz 0.00Hz
A112 02 end 0.00Hz 0.00Hz
-1500 to 1500
A113 02 start ratio -100% -100%
External
frequency
adjustment
A114 02 end ratio 100% 100%
-100 to 100
A131 Acceleration curve constant 02 02
Acceleration/
deceleration
A132 Deceleration curve constant 02 02
01 to 10 : Small swelling to Large swelling
b001 Retry selection 00 00
00: Trip, 01: 0 Hz start, 02: f-matched start, 03: trip after f-
matched gradual stop, 04: Restart at frequency before
momentary stop
b002 Allowable momentary stop time 1.0s 1.0s
0.3 to 25.0
b003 Retry wait time 1.0s 1.0s
0.3 to 100
b004
Momentary stop during stop/shortage
trip selection
00 00
00: Disabled, 01: Enabled, 02: Disabled during stop and
deceleration for stop
b005
Momentary stop/shortage retry count
selection
00 00
00: 16 times, 01: Unlimited
b006 Open phase selection 00 01
00: Disabled, 01: Enabled
Restart after
momentary
stop
b007 f-matched lower-limit frequency setting 0.00Hz 0.00Hz
0.00 to 1500
b012 First electronic thermal level 24A 24A
b212 Second electronic thermal level 24A 24A
0.2*(rated current) to 1.2*(rated current)
b013
First electronic thermal characteristics
selection
00 00
b213
Second electronic thermal
characteristics selection
00 00
00: Reduction characteristics, 01: Constant torque
characteristics, 02: Free setting
b015 Free electronic thermal frequency 1 0Hz 0Hz
0 to 1500
b016 Free electronic thermal current 1 0.0A 0.0A
0.0 to 1000
b017 Free electronic thermal frequency 2 0Hz 0Hz
0 to 1500
b018 Free electronic thermal current 2 0.0A 0.0A
0.0 to 1000
b019 Free electronic thermal frequency 3 0Hz 0Hz
0 to 1500
Electronic
thermal
b020 Free electronic thermal current 3 0.0A 0.0A
0.0 to 1000
b021 Overload limitation selection 01 01
00: Disabled, 01: Enabled at acceleration or constant-speed
operation time, 02: Enabled at constant-speed operation time
b022 Overload limitation level 36 36
0.5*(rated current) to 2*(rated current)
b023 Overload limitation constant 1.00s 1.00s
0.1 to 30
b024 Overload limitation 2 selection 01 01
00: Disabled, 01: Enabled at acceleration or constant-speed
operation time, 02: Enabled at constant-speed operation time
b025 Overload limitation level 2 36 36
0.5*(rated current) to 2*(rated current)
Overload
limitation
b026 Overload limitation constant 2 1.00s 1.00s
0.1 to 30
Lock b031 Soft lock selection 01 00
00: (When the SFT terminal is on) Items other than this item
cannot be modified., 01: (When the SFT terminal is on) Items
other than this item a frequency cannot be modified., 02: Items
other than this item cannot be modified.
b100 Free V/f frequency 1 0Hz 0Hz
0 to free V/f frequency 2
b101 Free V/f voltage 1 0.0V 0.0V
0 to 800.0
b102 Free V/f frequency 2 0Hz 0Hz
0 to free V/F frequency 3
b103 Free V/f voltage 2 0.0V 0.0V
0 to 800.0
b104 Free V/f frequency 3 0Hz 0Hz
0 to free V/F frequency 4
b105 Free V/f voltage 3 0.0V 0.0V
0 to 800.0
b106 Free V/f frequency 4 0Hz 0Hz
0 to free V/F frequency 5
b107 Free V/f voltage 4 0.0V 0.0V
0 to 800.0
b108 Free V/f frequency 5 0Hz 0Hz
0 to free V/F frequency 6
b109 Free V/f voltage 5 0.0V 0.0V
0 to 800.0
b110 Free V/f frequency 6 0Hz 0Hz
0 to free V/F frequency 7
b111 Free V/f voltage 6 0.0V 0.0V
0 to 800.0
b112 Free V/f frequency 7 0Hz 0Hz
0 to 400
Free V/f
b113 Free V/f voltage 7 0.0V 0.0V
0 to 800.0