B-70255EN/01 APPENDIX D.PARAMTER LIST
- 209 -
#7 #6 #5 #4 #3 #2 #1 #0
15009 TEM BCG BEM AFZ BS2 BS1 AS2 AS1
Data type: Bit
AS1,AS2,BS1,BS2 Parameters for the laser gas mixing function.
This function stores and monitors the operating status of the mixer.
These parameters need not be set manually because they are
automatically set.
AS2,AS1 Indicates the status of tank A.
AS2 AS1 Status
0 0 Filling gases in tank A
0 1 Mixing gases in tank A
1 0 Supplying gases in tank A
1 1 Setup for filling gases in tank A in progress
BS2 BS1 Status
0 0 Filling gases in tank B
0 1 Mixing gases in tank B
1 0 Supplying gases in tank B
1 1 Setup for filling gases in tank B in progress
AFZ
1: Does not include the Z-axis in calculation for actual cutting
feedrate display.
0: Includes the Z-axis in calculation for actual cutting feedrate
display.
BEM
1: The supply pressure of the three-gas cylinder is normal.
0: The supply pressure of the three-gas cylinder is low.
BCG
1: The three-gas cylinder is not replaced.
0: The three-gas cylinder is replaced.
TEM
1: The tank supply pressure is normal.
0: The tank supply pressure is low.
#7 #6 #5 #4 #3 #2 #1 #0
15010 OVE TRG
Data type: Bit
TRG
0: Disables the trigger pulse command control function.
1: Enables the trigger pulse command control function.
OVE
0: Does not allow edge machining and feedrate clamp based on arc
radius to be used together.
1: Allows edge machining and feedrate clamp based on arc radius
to be used together.