B-70255EN/01 4.INSTALLATION
- 41 -
Discharge aging
If the oscillator is left unused for a long time (three days or more), or
if the laser gas circulating system has been opened to the atmosphere
(for example, to clean the mirrors or replace gas system components),
aging is required. This involves warming up the discharge tubes and
circulating gas by performing internal discharge to output absorbent
contaminants as gas. If the laser gas circulating system has been
opened to the atmosphere, perform a leakage check before attempting
aging.
(1) Modify the parameters listed below.
PRM No.15000 bit 3
0 ® 1 (Internal discharge is enabled in manual mode.)
PRM No.15000 bit 4
1 ® 0 (Three-minute correction is disabled.)
PRM.No.15008 bit 6
1 ® 0 (Automatic aging is disabled.)
PRM No.15002 bit 0
0 ® 1 (Internal discharge is enabled in automatic operation
mode.)
PRM No.15003 bit 2
1 ® 0 (Evacuation is not performed after the RUN OFF.)
PRM No.15208
6144 ® 0 (Output feedback is turned off.)
PRM No.15209
100 ® 0 (Output feedback is turned off.)
PRM No.15242, 15243
Setting ® -100 (The discharge gas pressure is changed.)
(2) Set the RUN key to ON to start the oscillator. Perform discharge
by setting the HV ON switch to ON.
(3) Then, perform internal discharge for thirty minutes using the
settings indicated below. Two methods of internal discharge are
supported. One is automatic operation based on programming,
while the other is manual operation using switches.
Condition : 700, 100Hz, Duty 50%
· Automatic operation
1 Create the following program.
G32 P1 Q1 ;
G24 S700 P100 Q50 R900.; S is a power command.
G32 P0;
2 Lock the shutter, then start the program.
· Manual operation
This method can be used when the machine operator's panel
has a switch enabling manual internal discharge.
1 On the setting screen, enter the output power and duty
ratio.
2 Press the internal discharge switch to perform internal
discharge.