B-70255EN/01 6.TROUBLESHOOTING
- 69 -
Related parameters
PRM.15009#7 TEM Tank supply pressure
DGN.960#5 *MGP Laser gas supply pressure sensor
Cause of trouble Solution
1 Tool low supply pressure
of laser gas
Adjust the secondary pressure at the regulator
on the gas cylinder so that the pressure of
laser gas supplied to the laser oscillator is
0.1MPa (rating) as measured at the entry of
the oscillator. If the distance between the gas
cylinder and the oscillator is larger than 5 m, it
is necessary to set the pressure slightly higher.
2 No laser gas. Check whether the gas cylinder is empty or
whether the connection valve is closed. If
empty, replace the gas cylinder.
3 Leakage from the gas tube
leading to the oscillator
Check that the gas pipe joint is secure. Also
check whether the tube or pipe is broken. If so,
replace it.
4 Gas supply pressure
sensor or cable abnormal
Check whether the gas supply pressure
sensor is set correctly. If not, set the sensor as
explained in Chapter 9. If the sensor cannot be
reset, replace the sensor.
ALM No.4074
Roots blower overheat
This alarm is issued if the maximum allowable temperature of
the motor sequence section of the Roots blower is exceeded.
When an oscillator having turbo blowers is used, this alarm is
not issued.
Alarm output condition
This alarm is issued when the blower temperature signal becomes 0 during
the time from RUN-ON to immediately before purge completion. If bit 5 of
parameter No. 15003 is set to 1, however, the signal is not monitored.
Blower temperature signal
RBT (bit 6 at address 00H of DI of the laser interface)
Related parameters
PRM.15003#5 TON Presence of the turbo blower
DGN.960#6 *RBT Roots blower temperature
Cause of trouble Solution
1 Excessively high cooling water
temperature
Reduce the temperature of cooling water.
2 Insufficient cooling water The amount of cooling water being
supplied to the Roots blower may be
insufficient. Check whether the cooling
water tube between the water branch unit
and Roots blower is twisted or clogged. If
the tube is twisted or clogged, replace the
tube.
3 Anomaly in temperature sensor
cable connection
Check whether the cable is securely
connected to the temperature sensor. If
not, reattach the cable.