4.INSTALLATION B-70255EN/01
- 36 -
(d) Upon the completion of this check, close the main valve of
the gas cylinder.
CAUTION
Periodically check the external gas piping for
leakage.
Parameter check
Laser oscillator parameter data sheets are attached to each oscillator.
Machine tool builders may prepare a parameter table including the
laser oscillator parameter data. If the attached parameter data sheets
are missing, contact your machine tool builder.
(1) On the CNC setting screen, enable parameter rewriting.
(2) Check the parameters, and enter the same values as those given
in the parameter table.
(3) On the CNC setting screen, disable parameter rewriting, then
press the reset key.
CAUTION
1 If the oscillator is started with an incorrect parameter
value specified, there is a risk of the oscillator being
damaged or destroyed. Be particularly careful when
entering and checking parameter values.
2 Some parameters may require modification to, for
example, suit the operating state of the oscillator or
enable maintenance. When modifying the
parameters, the user should record all changes
(including dates, parameters before modification,
parameters after modification, and reasons for
modification) so that old parameters and invalid
parameters are not used.
Check for leakage within the oscillator
(1) Modify the parameters listed below.
PRM.No.15008 bit 6 1 ® 0 (Automatic aging is disabled.
PRM No.15240 Setting® 0 (evacuation completion pressure)
(2) Set the oscillator start switch to ON. The gas pressure inside the
oscillator can be checked with DGN 905.
(3) Alarm No. 4080 is issued eleven minutes after the oscillator is
started.
(4) Set the main circuit breaker of the oscillator to OFF. Then, turn
off the power to the CNC.
(5) Set the CNC start switch (RUN ON KEY) to OFF, then turn on
the power to the CNC.