B-70255EN/01 11.LASER OPTICAL SYSTEM
- 183 -
NOTE
Since the lens cleaner has a high surface tension, it
may be difficult to move the cleaning paper. As the
paper is slowly moved to and fro across the mirror,
however, the ethyl alcohol will gradually evaporate.
(9) Blow clean air (using, for example, a camera blower) across the
mirror surface to completely evaporate the ethyl alcohol or lens
cleaner.
(10) Repeat steps (7) to (9) until all dirt on the mirror surface has
been removed. Finally, clean the mirror surface with ethyl
alcohol.
(11) Check the transmitting side of the mirror. If its surface is dirty,
perform steps (6) to (9) for the transmitting side also. Note that if
an excessive amount of ethyl alcohol or lens cleaner is applied, it
may flow around the back of the mirror, leading to
contamination.
(12) Wipe the mirror holder and O-ring with ethyl alcohol.
(13) Reinstall the output mirror in the mirror holder, then insert the
O-ring. When installing the output mirror, pay particular
attention to the mirror orientation. The reflecting plane (the
plane indicated by the arrow on the side of the mirror) must face
the discharge tubes. The arrow is both scribed and marked with
ink such that, even if the ink is entirely removed, it will still be
possible to find the scribed arrow. Align the arrow on the side of
the output mirror with the mirror holder position.
(14) Mount the mirror by reversing steps (2) to (4). Install the mirror
holder in the alignment unit so that the mark on the mirror holder
faces down.
(15) Close the main circuit breaker or turn on the power supply of the
laser oscillator, then turn on the power to the CNC.
(16) Perform a leak check.
(17) This completes cleaning and replacement.
(18) Perform discharge aging.
(19) Then, perform alignment.
NOTE
Do not make any adjustments other than output
mirror alignment at this time.