4.INSTALLATION B-70255EN/01
- 30 -
Model Rated flow rate Pressure loss of the flow path in the
oscillator at rated flow rate
C1000iA
35 liters/minute 0.12 MPa
(e) Stop the chiller unit, then switch the operation mode from
manual (local) mode to automatic (remote) mode.
(f) If there is no water leakage, set the RUN key to ON to start
the oscillator. Check that the cooling water circulating unit
can be operated according to commands issued from the
CNC. If the flow rate is less than the specified value, alarm
No. 4072 (low cooling water flow rate) is issued soon after
the chiller unit is started. If this alarm is issued, proceed as
indicated in the guidance corresponding to this alarm.
(g) Check that the temperature of the cooling water is set to
room temperature plus 1°C. (The temperature of the cooling
water may be set to about 27°C throughout the year.) The
highest temperature that may be set is 30°C.
(11) Conduct an oscillator vacuum leakage test.
(a) Check the oscillator for any internal leakage.
The procedure for performing a leakage check is given in
Item (6) in Section 4.3.
(b) When first starting the oscillator, check that gas is output
from the gas outlet of the oscillator. Depending on the
parameter settings, it may take as long as one minute before
gas is output. If no gas is output, the exhaust pump rotation
may be reversed. Immediately turn off the circuit breaker to
stop the exhaust pump. If this situation is left uncorrected,
the exhaust pump may ultimately start to make an abnormal
sound, and the thermal switch may trip. In the worst case,
the gas circulating system may be contaminated with
exhaust pump oil.
(12) Check that the laser gas pressure is controlled normally.
(a) Set all bits of parameter No. 15025 through parameter No.
15028 to 0 because only the pressure control operation is to
be checked, without causing discharge. Set parameter No.
15240 to the standard value 10, then check the pressure
control status of the laser oscillator. Start the oscillator
(RUN ON), and check the pressure control status under the
following parameters while checking DGN905:
1. Parameter No. 15241 for discharge start state
2. Parameter No. 15242 for base discharge state
If the pressure control status is abnormal, alarm No. 4073 ,
No. 4081, or No. 4078 is issued. Proceed as indicated in the
guidance corresponding to this alarm. Check also that the
laser gas flow rate in the base discharge state satisfies the
specified value.
(b) If the laser gas flow rate is abnormal, perform adjustment as
described in Section 9.4.