ALM No.4065
Shutter anomaly
Alarm output condition
This alarm is issued when the shutter open command and the shutter status
do not match in LRDY or a later step of the sequence.
Shutter open signal
SHOP (bit 0 at address 05H of DO of the laser interface)
Shutter status signal
SHOF (bit 5 at address 01H of DI of the laser interface)
SHON (bit 4 at address 01H of DI of the laser interface)
If SHOP = 1, SHON = 1 and SHOF = 0 are regarded as normal.
If SHOP = 0, SHON = 0 and SHOF = 1 are regarded as normal.
Any state other than the above causes an alarm. When the SHOP status
changes, the alarm monitor is masked for the time set in parameter No.
15152 (default: 3 seconds).
Related parameters
DGN.961 #4 SHON Shutter open detection
DGN.961 #5 SHOF Shutter close detection
DGN.970 #5 SHOP Shutter open command
F200 #4 Shutter ON signal
F200 #3 Shutter OFF signal
See the following table, and check the operation status.
[Open] command
DGN No.973.bit0=1
[Close] command
DGN No.973.bit0=0
[Open] detector state signal
DGN No.961 bit 4
11001100
[Close] detector state signal
DGN No.961 bit 5
01010101
Normal(N)/Abnormal(A) N AAAAAAN
Cause of trouble Solution
1 Shutter clamp not removed. Remove the shutter clamp.
2 Anomaly of position detector Replace the position detector.
3 Shutter cam loosened. Tighten the screw again.
4 Shutter arm section caught Eliminate the cause of the problem. If
the problem cannot be solved, replace
the unit.
5 Relay PCB B (A16B-1600-
0361) is faulty.
Replace the relay PCB B.
6 Anomaly of cables connecting
each PCB.
Check the connection of each cable.
ALM No.4066
Discharge starting anomaly
After HV is turned on(start discharge), the discharge starts. This
alarm occurs when at least one discharge tube discharges hard
and causes high voltage.