4.INSTALLATION B-70255EN/01
- 38 -
(6) After completing the check, reset the value set in (3) above to the
original setting.
Oscillation characteristics
(1) Modify the parameters listed below.
PRM No.15000 bit 4
Setting ® 1 (Three-minute correction is enabled.)
PRM.No.15008 bit 6
1 ® 0 (Automatic aging is disabled.)
(2) Start the oscillator. When a discharge start switch is provided, do
not set the switch to ON until after LRDY has been set.
(3) When starting discharge, the oscillator enters the correction
mode in which output is specified automatically. Record the
output observed before correction ends.
(4) Record the output, discharge voltage, and current values two
minutes after making the specification. The discharge voltage
(RFV) is indicated in DGN909, and the current value (RFI) is
indicated in DGN910.
(5) Record the output observed immediately before correction ends
since the output is specified.
(6) After ending the correction mode, record compensation
coefficient [parameter No. 15204].
(7) Three minutes after the termination of correction mode, record
the base discharge output, discharge voltage (RFV), and current
(RFI) values.
Compare the measured values of (4) and (7), above, with the
discharge voltage and current characteristics given in the data sheets.
If the discharge voltage (RFV) is high, check the external piping of
the laser gas and the laser gas composition, or perform aging.
Discharge margin check
(1) Modify the parameters listed below.
PRM No.15000 bit 4
1 ® 0 (Three-minute correction is disabled.)
PRM.No.15008 bit 6
1 ® 0 (Automatic aging is disabled.)
PRM No.15208
Setting ® 0 (Output feedback is turned off.)
PRM No.15209
Setting ® 0 (Output feedback is turned off.)
PRM No.15223
Setting ® Setting -60