B-70255EN/01 4.INSTALLATION
- 29 -
(7) Check the input power supply voltage, frequency and phase
sequence. (See Section 6.5 for details.)
(8) Turn on the power, then check the operation of the fan motors in
the housing.
The fan motors installed in the oscillator start as soon as the
power to the CNC is turned on. Check the operation of each fan
motor. Note, however, that the fan motor installed in the laser
power supply does not start until the oscillator sequence reaches
the turbo blower ON operation.
(9) Check the parameters and setting data.
Check the parameters against the data sheets attached to the
oscillator. If a value other than those given on the data sheets is
set, correct the setting. Note, however, that parameter No. 15270
and parameter No. 15204 are set automatically, so that these
parameters need not be modified.
CAUTION
Each oscillator has unique parameters. Check the
setting data according to the attached data sheets.
Be particularly careful to store these data sheets
safely.
(10) Check that cooling water is supplied normally, and that there is
no water leakage inside the oscillator or at any external
connection points.
(a) Turn off the main circuit breaker of the oscillator and
power supply.
(b) Check that the water inlet (IN) and outlet (OUT) of the
oscillator are connected correctly. If the water inlet and
outlet are connected incorrectly, the flow sensor mounted
on the outlet does not function, which prevents water from
flowing.
(c) Fully open the valves on the exhaust side so that the flow of
water is not impeded. By manually operating the chiller unit,
pass cooling water through the system at a flow rate of
about 10 liters/minute. Then, check that there is no water
leakage at the following locations:
1. The water inlet (IN) and outlet (OUT) of the oscillator
2. The water piping (including all tubes and joints) in the
oscillator
(d) Provided no water leakage is observed in step 3) above,
allow cooling water to flow through the oscillator at the
specified flow rate. Set the output pressure of the cooling
water circulating unit to 0.5 MPa(5 bar). Then, check that
there is no water leakage at the following locations:
1. The water inlet (IN) and outlet (OUT) of the oscillator
2. The water piping (including tubes and joints) in the
oscillator