6.TROUBLESHOOTING B-70255EN/01
- 78 -
Cause of trouble Solution
turbo blower gas
circulating
performance
inverter are normal. Replace the turbo blower or
high-frequency inverter if found to be faulty.
ALM No.4089
Assist gas not output
This alarm is issued, if an attempt is made to radiate a laser beam,
when no assist gas is selected, or an assist gas condition is not
set up.
Alarm output condition
This alarm is issued when no assist gas is output during beam output.
Assist gas signal
AG1 to AG3(F0222#0 to #2)
Related parameters
F222#0 to #2 Assist gas selection signal
ALM No.4090
Laser beam not generated
This alarm is issued, if an attempt is made to radiate a laser beam,
when the laser oscillator is not in the LSTR state (discharging
state).
Alarm output condition
This alarm is issued when LSTR is not set during beam output.
Related parameters
F221#6 Oscillation in-progress signal
ALM No.4094
Vacuum pump operation abnormal
This alarm occurs when the thermal switch of the magnetic
contactor for the exhaust pump is tripped.
Alarm output condition
This alarm is issued when the exhaust pump operation signal RPAL
becomes 0 during the time from RUN-ON to immediately before purge
completion.
Exhaust pump operation signal
RPAL (bit 3 at address 01H of DI of the laser interface)
Related parameters
DGN.972 RPA Exhaust pump start
DGN.961#3 *RPAL Exhaust pump alarm
Cause of trouble Solution
1 Exhaust pump
operation abnormal
Replace the exhaust pump.
2 Anomaly of IF PCB If the thermal switch of the contactor does not trip, the
interface PCB is abnormal. Replace it.
3 Signal cable broken Replace the cable.