2. PARAMETERS FOR THE SPEED AND LOOP GAIN SWITCH
B–63690EN/01
14
PCT Constant control of positioning time is:
0: Invalidated.
1: Validated.
The parameter is validated when parameter KLV (No. 16050,
#7) is set to 1.
See the descriptions of parameters 16095 to 16102.
KLV When rapid traverse is executed in automatic operation, the
function to change the time constant and X–axis and Y–axis
rapid traverse feedrates among seven levels according to the
positioning distance is:
0: Invalidated.
1: Validated. See the descriptions of data 16055 to 16094.
#7 #6 #5 #4 #3 #2 #1 #0Address
16051 PGC VGC LPG KLT
Data type: Bit
KLT When rapid traverse is executed in automatic operation, the
function to change the servo loop gain of position control and
time constant of T–axis rapid traverse among three levels
according to the indexed angle is:
0: Invalidated.
1: Validated.
See the descriptions of parameters 16117 to 16124.
LPG When rapid traverse is executed in automatic operation, the
function to change the servo loop gain of X–axis and Y–axis
position control among seven levels according to the
positioning distance is:
0: Invalidated.
1: Validated.
The parameter is validated when parameter KLV (No. 16050,
#7) is set to 1.
See the descriptions of parameters 16103 to 16116.
VGC During automatic operation, the velocity loop gain, position
gain, and PI/IP control switching functions for the X– and
Y–axes are:
0: Disabled
1: Enabled
When this parameter is set to 1, parameters N3S (bit 2 of No.
16050), KLV (bit 7 of No. 16050), PIN and PIP (bits 3 and 2 of
No. 16054), and Nos. 16828 to 16843 are also used.
PGC Servo loop gains of X–axis and Y–axis position control to be
used in rapid traverse and cutting feed:
0: Are the same.
1: Can be set separately. See the description of parameter
16160.