11. SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
B–63690EN/01
64
Address
16822 Velocity loop integral gain for first stage
16823 Velocity loop integral gain for second stage
16824 Velocity loop integral gain for third stage
Data type: Word axis
Valid data range: 1 to 32767
When using three–stage switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
velocity loop integral gains. (Equivalent to parameter No. 2043)
Only the settings for the X– and Y–axes are valid.
These parameters are valid when bit 5 (VCG) of parameter No. 16051 is
set to 1.
Address
16825 Velocity loop proportional gain for first stage
16826 Velocity loop proportional gain for second stage
16827 Velocity loop proportional gain for third stage
Data type: Word axis
Valid data range: –1 to 32767
When using three–stage switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
velocity loop proportional gains. (Equivalent to parameter No. 2044)
Only the settings for the X– and Y–axes are valid.
These parameters are valid when bit 5 (VCG) of parameter No. 16051 is
set to 1.