B–63690EN/01
2. PARAMETERS FOR THE SPEED AND LOOP GAIN SWITCH
17
Address
16061 Distance D1 to level 1 (in inches)
16062 Distance D2 to level 2 (in inches)
16063 Distance D3 to level 3 (in inches)
16064 Distance D4 to level 4 (in inches)
16065 Distance D5 to level 5 (in inches)
16066 Distance D6 to level 6 (in inches)
Data type: Two–word
Unit of data:
Increment system IS–A IS–B Units
Input in milimeters 0.01 0.001 mm
Input in inches 0.001 0.0001 inch
Valid data range: 0 to 99999999
Each of the parameters set the positioning distance to use the function to
change the time constant and X–axis and Y–axis rapid traverse feedrate
among seven levels according to the positioning distance. (Identical
values are set for the X and Y axes.)
The data is validated when parameter KLV (No. 16050, #7) is set to 1.
NOTE
1 The values set here must satisfy the following relationship:
D1 < D2 < D3 < D4 < D5 < D6.
2 The values can be changed among seven levels or less.
When the values are to be changed among four levels, set
D4 to 99999999.
Address
16067 X–axis rapid traverse feedrate of level 1
16068 X–axis rapid traverse feedrate of level 2
16069 X–axis rapid traverse feedrate of level 3
16070 X–axis rapid traverse feedrate of level 4
16071 X–axis rapid traverse feedrate of level 5
16072 X–axis rapid traverse feedrate of level 6
16073 X–axis rapid traverse feedrate of level 7
Data type: Two–word
Unit of data:
Valid data range:
Increment system Units of data Valid data range
Millimeter machine 1 mm/min 30 to 240000
Inch machine 0.1 inch/min 30 to 96000