5. PARAMETERS FOR THE PUNCH AND
LASER SWITCH
B–63690EN/01
32
5
PARAMETERS FOR THE PUNCH AND LASER SWITCH
#7 #6 #5 #4 #3 #2 #1 #0Address
16240 RLM ALA
Data type: Bit
ALA Switching between the punching mode and laser mode is:
0: Invalidated.
1: Validated.
RLM When the power is turned on or in the clear status, the machine
is set in the:
0: Punching mode.
1: Leser mode.
#7 #6 #5 #4 #3 #2 #1 #0Address
16241 ILM
Data type: Bit
ILM In a block other than cutting feed blocks or blocks between the
two cutting feed blocks when the laser mode is selected, the next
block is started:
0: After the following is checked: The specified speed is
reduced to zero and the machine reaches the specified
position. (A position check is carried out.)
1: After checking that the specified speed is reduced to zero.
(No position check is carried out.)
The parameters are validated when parameter ALA (No. 16240,
#0) is set to 1.
In punching mode, the NCI bit (bit 5 of parameter 1601) is valid.
Address
16244 M code for setting the punching mode
16245 M code for setting te leser mode
Data type: Byte
Valid data range: 0 to 255
Each of the parameters set the M code for setting the punching mode or
leser mode.
The parameters are validated when parameter ALA (No. 16240, #0) is set
to 1.