8. PARAMETERS (1) FOR THE SAFETY ZONE
B–63690EN/01
52
T16 The number of tool areas to be used is:
0: Up to 12.
1: Up to 16.
This parameter is valid if the safety zone area extension function
is specified.
Address
16505 Positive X coordinate for safety zone 1
16506 Negative X coordinate for safety zone 1
16507 Y coordinate for safety zone 1
16508 Positive X coordinate for safety zone 2
16509 Negative X coordinate for safety zone 2
16510 Y coordinate for safety zone 2
16511 Positive X coordinate for safety zone 3
16512 Negative X coordinate for safety zone 3
16513 Y coordinate for safety zone 3
16514 Positive X coordinate for safety zone 4
16515 Negative X coordinate for safety zone 4
16516 Y coordinate for safety zone 4
Data type: Two-Word
Unit to data:
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Valid data range: 0 to "99999999
Each set of the parameters specify safety zone 1, 2, 3, or 4.
NOTE
1 The values set for zone #n must be smaller than those set
for zone #n + 1. (n: 1 to 3)
2 Zeros must be specified for zones which need not be
specified.
3 If any of the +X, –X, and Y coordinates are set to 0 for an
area, that area is invalid.