B–63690EN/01
12. PARAMETERS (2) FOR THE SAFETY ZONE
71
12
PARAMETERS (2) FOR THE SAFETY ZONE
Address
16930 Positive X coordinate for safety zone 5
16931 Negative X coordinate for safety zone 5
16932 Y coordinate for safety zone 5
16933 Positive X coordinate for safety zone 6
16934 Negative X coordinate for safety zone 6
16935 Y coordinate for safety zone 6
16936 Positive X coordinate for safety zone 7
16937 Negative X coordinate for safety zone 7
16938 Y coordinate for safety zone 7
16939 Positive X coordinate for safety zone 8
16940 Negative X coordinate for safety zone 8
16941 Y coordinate for safety zone 8
Data type: Two-Word
Unit to data:
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Valid data range: 0 to "99999999
Each set of the parameters specify safety zone 5, 6, 7, or 8.
Refer to parameters No.16505 to No.16516.
These parameters are valid if the safety zone area extension function is
specified.
NOTE
1 The values set for zone #n must be smaller than those set
for zone #n + 1. (n: 1 to 7)
2 Zeros must be specified for zones which need not be
specified.
3 If any of the +X, –X, and Y coordinates are set to 0 for an
area, that area is invalid.