12. PARAMETERS (2) FOR THE SAFETY ZONE
B–63690EN/01
72
Address
16942 X dimension of tool area 13 for the safety zone function
16943 Y dimension of tool area 13 for the safety zone function
16944 X dimension of tool area 14 for the safety zone function
16945 Y dimension of tool area 14 for the safety zone function
16946 X dimension of tool area 15 for the safety zone function
16947 Y dimension of tool area 15 for the safety zone function
16948 X dimension of tool area 16 for the safety zone function
16949 Y dimension of tool area 16 for the safety zone function
Data type: Two-Word
Unit to data:
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Valid data range: 0 to 99999999
The parameters set 16 tool areas for the safety zone function.
Refer to parameters No. 16517 to No. 16532 and No. 16551 to 16558.
These parameters are valid if the safety zone area extension function is
specified.
NOTE
A tool area is selected by signals SZTS0 to SZTS3 input
from a PMC machine.