B–63690EN/01
2. PARAMETERS FOR THE SPEED AND LOOP GAIN SWITCH
23
Address
16145 C–axis rapid traverse time constant of level 1
16146 C–axis rapid traverse time constant of level 2
16147 C–axis rapid traverse time constant of level 3
Data type: Word
Unit of data: msec
Valid data range: 8 to 4000
Each of the parameters set the C–axis rapid traverse to use the function
for changing the C–axis rapid traverse feedrate and rapid traverse time
constant among three levels according to the positioning angle.
See the descriptions of parameters 16140 and 16141.
Address
16160 Servo loop gain in cutting feed
Data type: Word axis
Unit of data: 0.01 sec
–1
Valid data range: 1 to 9999
For each axis, the parameter sets the servo loop gain of position control
in cutting feed.
The parameter is validated when parameter PGC (No. 16051, #7) is set
to 1.
NOTE
The parameter can only be set for the X and Y axes.