B–63690EN/01
11. SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
65
Address
16828 Velocity loop integral gain for first stage
16829 Velocity loop integral gain for second stage
16830 Velocity loop integral gain for third stage
16831 Velocity loop integral gain for fourth stage
16832 Velocity loop integral gain for fifth stage
16833 Velocity loop integral gain for sixth stage
16834 Velocity loop integral gain for seventh stage
Data type: Word axis
Valid data range: 1 to 32767
When using seven–stage velocity loop gain switching, use these
parameters to set the velocity loop integral gains. (Equivalent to
parameter No. 2043)
Only the settings for the X– and Y–axes are valid.
Address
16835 Velocity loop proportional gain for first stage
16836 Velocity loop proportional gain for second stage
16837 Velocity loop proportional gain for third stage
16838 Velocity loop proportional gain for fourth stage
16839 Velocity loop proportional gain for fifth stage
16840 Velocity loop proportional gain for sixth stage
16841 Velocity loop proportional gain for seventh stage
Data type: Word axis
Valid data range: –1 to 32767
When using seven–stage velocity loop gain switching, use these
parameters to set the velocity loop proportional gains. (Equivalent to
parameter No. 2044)
Only the settings for the X– and Y–axes are valid.