B–63690EN/01
8. PARAMETERS (1) FOR THE SAFETY ZONE
57
Address
16559
Width of tool area along the X–axis for the function used to prevent interfer-
ence between workpiece holders
16560
Width of tool area along the Y–axis for the function used to prevent interfer-
ence between workpiece holders
Data type: Two-Word
Unit to data:
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Valid data range: 0 to 99999999
Each of the parameters is specified to add a margin to the tool area when
interference between the tool area (parameters 16517 to 16532) and safety
zone area (parameters 16505 to 16516) is checked, to output the WHAL
signal (F231, #5), by the function used to prevent interference between
workpiece holders. The parameter value is added to the tool area width
when interference is checked.
Address
16561
Compensation value used by the function used to prevent interference
between workpiece holders
Data type: Two-Word
Unit to data:
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Valid data range: 0 to 99999999
This parameter specifies a compensation value for retraction along the
Y–axis when the function used to prevent interference between workpiece
holders of type B is used. This parameter is valid when the ACZ bit (bit
6 of parameter 16502) is set to 1.
Y area of the workpiece holder
Clamp
#1 #2
Clamp
d: Setting value
Y
X