11. SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
B–63690EN/01
68
Address
16857 Time during which PF is set to 1 prior to end of positioning for first stage
16858 Time during which PF is set to 1 prior to end of positioning for second stage
16859 Time during which PF is set to 1 prior to end of positioning for third stage
16860 Time during which PF is set to 1 prior to end of positioning for fourth stage
16861 Time during which PF is set to 1 prior to end of positioning for fifth stage
16862 Time during which PF is set to 1 prior to end of positioning for sixth stage
16863 Time during which PF is set to 1 prior to end of positioning for seventh stage
Data type: Byte axis
Units of data: msec
Valid data range: 0 to "120
Set the time during which the press start signal PF is set to 1 prior to the
end of the positioning corresponding to each positioning distance (PF
early output function).
These parameters are valid for those axes for which bit 7 (KL2j) of
parameter No. 16844 is set to 1.
Address
16864 Rapid traverse rate for first stage
16865 Rapid traverse rate for second stage
16866 Rapid traverse rate for third stage
16867 Rapid traverse rate for fourth stage
16868 Rapid traverse rate for fifth stage
16869 Rapid traverse rate for sixth stage
16870 Rapid traverse rate for seventh stage
Data type: Two–word axis
Units of data:
Valid data range:
Increment system Units of data Valid data range
Millimeter machine 1 mm/min 30 to 240000
Inch machine 0.1 inch/min 30 to 96000
Rotary axis 1 deg/min 30 to 240000
Set the rapid traverse rate for each positioning distance, for each axis.
These parameters are valid for those axes for which bit 7 (KL2j) of
parameter No. 16844 is set to 1.