B–63690EN/01
11. SPEED AND SERVO PARAMETER
SWITCHING PARAMETERS
63
Address
16810 PF output time prior to end of first stage positioning for X–axis
16811 PF output time prior to end of second stage positioning for X–axis
16812 PF output time prior to end of third stage positioning for X–axis
16813 PF output time prior to end of first stage positioning for Y–axis
16814 PF output time prior to end of second stage positioning for Y–axis
16815 PF output time prior to end of third stage positioning for Y–axis
Data type: Byte
Units of data: msec
Valid data range: –128 to 120
When using three–stage switching for constant positioning time control
for the X– and Y–axes during nibbling, use these parameters to set the
time during which PF is to be output prior to the end of positioning.
These parameters are valid when bit 3 (NPF) of parameter No. 16181 is
set to 1.
Address
16816 First stage position gain for X–axis
16817 Second stage position gain for X–axis
16818 Third stage position gain for X–axis
16819 First stage position gain for Y–axis
16820 Second stage position gain for Y–axis
16821 Third stage position gain for Y–axis
Data type: Word
Units of data: 0.01 sec
–1
Valid data range: 1 to 9999
When using three–stage switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
position gains.
These parameters are valid when bit 4 (LPG) of parameter No. 16051 is
set to 1.