B–63690EN/01
1. PARAMETERS OF THE PRESS FUNCTION
1
1
PARAMETERS OF THE PRESS FUNCTION
#7 #6 #5 #4 #3 #2 #1 #0Address
16000 PEI NFI PFI RPF HCI HSP
Data type: Bit
HSP High–speed press control is:
0: Disabled.
1: Enabled.
The following functions cannot be used:
S Servo waveform display (The correct waveform cannot
be displayed while this function is being used.)
S Axis control by PMC (PMC axis cannot be controlled
while this function is being used)
S Advanced preview control
S Using the simple synchronous control function for
multiple pairs of axes (excluding Cs synchronization
control)
HCI Under high–speed press control, the *PFIN signal to complete
punching for single–cycle pressing, and the *NFIN signal to
complete punching for continuous pressing are valid for:
0: Standard address (X004).
When this is selected, the maximum stop time, from
when the punching complete signal is input until
movement along an axis starts, is 7 msec.
1: High–speed DI address HDI0 (both *PFIN and *NFIN).
When this is selected, the maximum stop time, from
when the punching complete signal is input until
movement along an axis starts, is 3 msec.
RPF When the RESET key is pressed or when external reset, reset
and rewind, or emergency stop is activated, the PF signal to start
pressing is:
0: Set to 0.
1: Not set to 0.
PF is set to 0 only when the *PE signal to stop pressing is set
to 0.
PFI The logic of the *PFIN signal to complete punching for
single–cycle pressing is:
0: The same as the logic described in the ”Connection
Manual.”
1: The reverse of the logic described in the ”Connection
Manual.”