B–63690EN/01
4. PARAMETERS FOR THE PATTERN FUNCTION
27
4
PARAMETERS FOR THE PATTERN FUNCTION
#7 #6 #5 #4 #3 #2 #1 #0Address
16200 UVW ABM MUR UVC
Data type: Bit
UVC In the reset status, the macro stored under a U or V macro
number is:
0: Deleted.
1: Not deleted.
NOTE
When the parameter is set to 1, two or more macros with
identical numbers may often be stored. It takes a long time
to process the storage of macros.
MUR U or V macro numbers are handled:
0: According to the standard specifications.
1: According to the following specifications.
(1) Changing a macro number
Storage and execution: U01 to U69 and U90 to U99
Storage: U70 to U79
Representation of several macros: U80 to U89
(2) Macro numbers are handled in the same way as when
parameter 16206 of the G73 or G74 command for
taking multiple workpieces is set to 2.
NOTE
Parameter 16206 is invalidated.
ABM To store and call a pattern, addresses A and B:
0: Are used.
1: Are not used. (The A and B axes can be used.)
UVW To execute a macro function, addresses U, V, and W:
0: Are used.
1: Are not used. (The U, V, and W axes can be used.)