1. PARAMETERS OF THE PRESS FUNCTION
B–63690EN/01
2
NFI The logic of the *NFIN signal to complete punching for
continuous pressing is:
0: The same as the logic described in the “Connection
Manual.”
1: The reverse of the logic described in the “Connection
Manual.”
PEI The logic of the *PE signal to stop pressing is:
0: The same as the logic described in the “Connection
Manual.”
1: The revese of the logic described in the “Connection
Manual.”
#7 #6 #5 #4 #3 #2 #1 #0Address
16001 CPF MPF PMA PSY PE2 PRC PFE MNP
Data type: Bit
MNP If there remains a distance to be traveled when automatic
operation is halted, manual pressing or continuous manual
pressing is:
0: Validated.
1: Invalidated.
PFE When the PF signal to start pressing is set to 1, the absolute
value of positional deviation for the X– and Y– axes:
0: Must be less than or equal to the value set in paramter
16010.
1: Need not be less than or equal to the value set in parameter
16010.
PRC When the machine lock signal, MLK, is set to 1, a program
check is:
0: Not executed.
1: Executed.
The machine position data is updated although the actual
position is not changed. This setting is invalid for the machine
lock signal of each axis.
PE2 To output the PF signal to start pressing, position check is
executed at intervals of:
0: 8 msec.
1: 2 msec.
PSY Under simple synchronous control, the PF signal to start
pressing is output:
0: Irrespective of the machine coordinates of the
synchronous axes.
1: After it has been confirmed that the machine coordinates
of the synchronous axes agree with each other.
If the machine coordinates differ, alarm 213 will be issued and
the PF signal will not be output.
PMA When the AFL signal to lock miscellaneous functions is set to
1, M code signals for forming, repositioning, and nibbling are:
0: Not output to the machine.
1: Output to the machine.