10. PARAMETERS FOR CANCELLING Y–AXIS GAP
B–63690EN/01
60
Address
16680 Position of machine zero point 1 on T–axis
16681 Position of machine zero point 2 on T–axis
16682 Position of machine zero point 3 on T–axis
16683 Position of machine zero point 4 on T–axis
16684 Position of machine zero point 5 on T–axis
16685 Position of machine zero point 6 on T–axis
16686 Position of machine zero point 7 on T–axis
16687 Position of machine zero point 8 on T–axis
16688 Position of machine zero point 9 on T–axis
16689 Position of machine zero point 10 on T–axis
16690 Position of machine zero point 11 on T–axis
16691 Position of machine zero point 12 on T–axis
16692 Position of machine zero point 13 on T–axis
16693 Position of machine zero point 14 on T–axis
16694 Position of machine zero point 15 on T–axis
16695 Position of machine zero point 16 on T–axis
Data type: Two-Word
Unit to data: Least command increment for T–axis
Valid data range: 0 to 99999999
When the machine coordinate of the T–axis matches a position specified
in parameters 16680 to 16695, the corresponding signal RP1T to RP16T
(F244, F245) is output.
#7 #6 #5 #4 #3 #2 #1 #0Address
16747 SUV
Data type: Bit
This parameter can be changed using the setting screen.
SUV In the reset state, the macros stored under U or V macro numbers
are:
0: Deleted.
1: Not deleted.
This parameter is valid when the UVC bit (bit 0 of parameter
16200) is set to 1.