6. PARAMETERS FOR THE TURRET AXIS
B–63690EN/01
34
#7 #6 #5 #4 #3 #2 #1 #0Address
16262 MBT DTF TNA TND TDP PWT JGT NTD
Data type: Bit
NTD The tool data input screen is:
0: Displayed.
1: Not displayed.
JGT On the position display screen in jog mode, a T code (tool
number) is:
0: Not displayed by a signal input from the PMC.
1: Displayed by a signal (addresses G234 to G237) input
from the PMC.
PWT When the power is turned on, the T code (tool number) on the
position display screen is:
0: Set to 0.
1: Represented by signal input from the PMC machine
(addresses G234 to G237).
TDP On the position screen, a T code is:
0: Not displayed.
1: Displayed.
This parameter is valid when the TCL bit (bit 4 of parameter
16260) is set to 1 and when the NDPx bit (bit 0 of parameter
3115) is set to 0.
TND When the T–axis position is displayed,
0: The current position is indicated in units of minimum
travel increments.
1: The number of the tool at the current position is indicated.
This is validated when TDP (No. 16262, #3) is set to 1.
TNA When a tool number which is not cataloged is specified,
0: Alarm 4692 is issued.
1: No alarm are issued but a T code is output.
This must be specified when a T code with five or more digits
is specified and TCL (No. 16260, #4) is set to 1.
DTF When T codes are specified in automatic operation, a TF signal
for reading the code of the tool function and the tool function
code signal are output:
0: For each T code.
1: For the first T code command when the machine enters the
status in which automatic operation is started from the
status in which automatic operation is halted or stopped.
For the second and subsequent T code commands
specified until the machine returns to the status in which
automatic operation is halted or stopped, the TF signal and
tool function code signal are output only when the T code
signal is different from the previous one.
MBT In a block in which a T code is specified, buffering is:
0: Executed.
1: Not executed.