4. CONFIRMATION OF
THE OPERATION START-UP PROCEDURE B-65165E/02
- 72 -
4.3.6.3 Observation method
By setting data using four DIP switches on the check board, you can
output internal data to the five-digit display, analog voltage output
circuit, channels 1 and 2 (LM and SM or CH1 and CH2).
Data on channels 1 and 2 is the one from an 8-bit D/A convertor.
The correspondence between channel 1/2 and the check terminal is
listed below.
Check terminal
Measurement point
A20B-2001-0830 A20B-1005-0740
Channel 1 CH1
CH1D, data bit 0
LM
Channel 2 CH2
CH2D, data bit 0
SM
NOTE
When using printed-circuit board A20B-1005-0740,
set DIP switches S2 and S3 on the spindle amplifier
module front panel to OFF. After observation, set
them to ON.
This operation is not necessary when you use
printed-circuit board A20B-2001-0830.
DIP switch ON position OFF position
S2, S3 Output voltage is
filtered out.
Output voltage is not
filtered out.