4. CONFIRMATION OF
B-65165E/02 START-UP PROCEDURE THE OPERATION
- 57 -
(Continued)
No. Description Action
18 Although the parameter not to use the
position coder signal (FS16i: bit 2 of
parameter No. 4001 = 0) is set, a
position coder orientation command
(ORCMA) is input.
Check the parameter setting
(FS16i: bit 2 of parameter No.
4001) and the PMC signal
(ORCM).
19 During magnetic sensor orientation,
another operation mode is specified.
Do not specify another operation
mode during execution of the
orientation command. Before
entering another mode, cancel the
orientation command.
20 When the use of the slave operation
mode function (FS16i: bit 5 of
parameter No. 4014 = 1) is set, the use
of a high-resolution magnetic pulse
coder (FS16i: bit 5 of parameter No.
4001 = 1) or the use of the Cs contour
control function by the α sensor (FS16i:
bit 4 of parameter No. 4018 = 1) is set.
These settings cannot be made at the
same time.
Check the parameter settings
(FS16i: bit 5 of parameter No.
4001, bit 5 of parameter No. 4014,
and bit 4 of parameter No. 4018).
21 During position control (such as servo
mode and orientation), a slave
operation mode command (SLV) is
input.
Input the slave operation mode
command (SLV) in normal
operation mode.
22 In slave operation mode (SLVS = 1), a
position control command (such as
servo mode and orientation) is input.
Input the position control
command in normal operation
mode.
23 Although the parameter not to use the
slave operation mode function (FS16i:
bit 5 of parameter No. 4014 = 0) is set,
the slave operation mode command
(SLV) is input.
Check the parameter setting
(FS16i: bit 5 of parameter No.
4014) and the PMC signal (SLV).
24 After orientation is performed in
incremental mode (INCMD = 1) first, an
absolute position command (INCMD =
0) is input next.
Check the PMC signal (INCMD).
Perform an absolute position
command orientation first.
25 Although the spindle amplifier is not
SPM type 4, the use of the Cs contour
control function by the α sensor (FS16i:
bit 4 of parameter No. 4018 = 1) is set.
Check the spindle amplifier
specification and parameter
setting (FS16i: bit 4 of parameter
No. 4018).