4. CONFIRMATION OF
B-65165E/02 START-UP PROCEDURE THE OPERATION
- 55 -
4.3.3 Status Error Indication Function
When there is a sequence or parameter error, the error LED (yellow) in
the display section of the spindle amplifier module (SPM) goes on with
an error code displayed. This can ease troubleshooting at the time of
machine startup.
The error LED
(yellow) lights.
An error code is indicated. (from 01)
status
When the spindle amplifier module does not operate for a certain
function, check whether the status error is indicated. The status error
number does not appear on the CNC screen.
No. Description Action
01 Although neither *ESP (emergency
stop signal) (there are two types of
signals, a PMC signal and PSM contact
signal) nor MRDY (machine ready
signal) has been input, SFR (forward
rotation signal), SRV (reverse rotation
signal), or ORCM (orientation
command) is input.
Check the *ESP and MRDY
sequences. (For MRDY, pay
attention to the parameter that
specifies whether to use the
MRDY signal (FS16i: bit 0 of
parameter No. 4001).)
02 When the spindle motor is equipped
with a high-resolution magnetic pulse
coder (Cs sensor) (FS16i: bits 6 and 5
of parameter No.4001 = 0, 1), 128 λ/rev
must be set for the speed detector
(FS16i: bits 2, 1, and 0 of parameter
No. 4011 = 0, 0, 1). However, other
than 128 λ/rev is set. In this case, the
motor is not activated.
Check the speed detector
parameter of the spindle motor
(FS16i: bits 2, 1, and 0 of
parameter No. 4011).
03 Although the use of a high-resolution
magnetic pulse coder (FS16i: bit 5 of
parameter No. 4001 = 1) or the use of
the Cs contour control function by the α
sensor (FS16i: bit 4 of parameter No.
4018 = 1) is not specified, a Cs control
command is input. In this case, the
motor is not activated.
Check the parameters of the
detector for Cs contour control
(FS16i: bit 5 of parameter No.
4001 and bit 4 of parameter No.
4018).
04 Although the parameter for using the
position coder signal (FS16i: bit 2 of
parameter No. 4001 = 1) is not set, a
command for servo mode (rigid tapping
or spindle positioning) or spindle
synchronization is input. In this case,
the motor is not activated.
Check the parameter of the
position coder signal (FS16i: bit 2
of parameter No. 4001).
05 Although no orientation option is set, an
orientation command (ORCM) is input.
Check the software option for
orientation.
(Continued)