4/4
SHEET
DRAW. No.
CUST.
TITLE
Addition of alarms for α series
spindle amplifier.
4 Alarm code 74
[Meaning]
The CPU operation is faulty.
[Cause and troubleshooting]
The control printed circuit board in the spindle amplifier is faulty.
Replace the control printed circuit board in the spindle amplifier or the spindle
amplifier.
5 Alarm code 75
[Meaning]
Error is detected in the CRC test when the spindle amplifier is turned on.
[Cause and troubleshooting]
The control printed circuit board in the spindle amplifier is faulty.
Replace the control printed circuit board in the spindle amplifier or the spindle
amplifier.
6 Alarm code 79
[Meaning]
ROM, RAM and CPU tests are not performed when the spindle amplifier is
turned on.
[Cause and troubleshooting]
The control printed circuit board in the spindle amplifier is faulty.
Replace the control printed circuit board in the spindle amplifier or the spindle
amplifier.
7 Alarm code 80
[Meaning]
Any alarm occurs in the other spindle amplifier when the communication
function between two amplifiers (Spindle EGB or Spindle tandem control) is
used.
[Troubleshooting]
Remove the alarm factor of the other spindle amplifier.