4. CONFIRMATION OF
THE OPERATION START-UP PROCEDURE B-65165E/02
- 50 -
4.3.1 STATUS Display
PIL
ALM
ERR
STATUS
No. ALM ERR STATUS Description
1. No
indication
The PIL LED (power ON indicator) is off.
The control power supply has not been
switched on.
The power supply circuit is defective. See
Section 3.1.2.
2. 20
↓
For about 1.0 s after the control power
supply is switched on, the lower two digits of
the ROM series No. are indicated.
Example) 20: ROM series No. 9D20
3. 04 The ROM edition number is displayed for
about 1.0 s. 01, 02, 03, and so on
correspond to A, B, C, and so on,
respectively.
Example) 04: ROM edition D
4. --
Blinking
The CNC has not been switched on.
The machine is waiting for serial
communication and parameter loading to
end.
5. --
Lighting
Parameter loading has ended.
The motor is not supplied with power.
6. 00 The motor is supplied with power.
7. Lighting 01 or
above is
displayed.
Alarm state
The SPM is not operable.
See Section 3.4 of Part II.
8. Lighting 01 or
above is
displayed.
Error state
Incorrect parameter setting or improper
sequence.
See Section 4.3.3 of Part II.
The PIL lamp is always on while the control power is being supplied.