B–63173EN/03
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
107
The connector panel I/O module can be connected directly to a
customer–designed connector panel printed–circuit board. It can also be
installed on the DIN rail.
In an I/O module for local lines, up to three extended units can be added
to a single basic unit. The basic unit and the additional extended units
form a single FANUC I/O Link group. The following basic unit and
extended units are available. (Multiple extended units of the same type
can be added.)
Unit name Drawing No. Specifications
Basic A03B–0815–C001 DI/DO : 24/16
Extended A A03B–0815–C002 DI/DO : 24/16
MPG interface incorporated
Extended B A03B–0815–C003 DI/DO : 24/16
MPG interface not incorporated
Extended C A03B–0815–C004 DO : 16
2A output
Extended D A03B–0815–C005 Analog input
6.7
CONNECTION OF
CONNECTOR PANEL
I/O MODULE
6.7.1
General