B–63173EN/03
10. CONNECTION TO PERIPHERALS
385
1
FG SD RD RS CS DR SG CD
2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
ER +24
1 RD
2 0V
3 DR
4 0V
11 SD
12 0V
13 ER
14 0V
5 CS
6 0V
7
8 0V
15 RS
16 0V
17
18
9 19
(0V)
Power Mate
JD5
(PCR-EV20MDT)
10
(RDB)
20
FG
FANUC
HANDY
FILE
Relaying
cable
Relaying connector
Connector : DBM-25S
(JAPAN AVIATION
ELECTRONIC
INDUSTRY., LTD.)
Lock metal : D20418-J2
(JAPAN AVIATION
ELECTRONIC
INDUSTRY., LTD.)
Appendant
Relaying connector signal layout
24 VDC
Stabilized
power
supply
+24VDC
10%
1.0A
0V is
connected
to SG.
CD (SDB)
NOTE
1 Machine tool builder shall furnish relay connector, relay
cable and 24VDC.
2 Use a totally shielded cable for the signal cable.
Recommended cable specification : A66L-0001-0284#10P
(Line length : 15m or less)
3 Open all terminals other than illustrated.
4 Set a parameter to be able to use reader puncher interface
when connecting Handy File.
The baud rate is 4800 baud.
5 24 VDC power for the FANUC Handy File must be supplied
from an external 24 VDC power supply or the CP2 power
output of the Power Mate (see Section 5.7).
10.1.5
Connection to the
Handy File (Channel 1)