8. CONNECTION TO SETTING AND DISPLAY UNIT
B–63173EN/03
234
(1)When there is only one unit of Power Mate
Power Mate
JD41 JD13
#0
(NOTE1)
J142
CRT/MDI
CPD1
JN1 FG
24VDC
power source
1.0A (Stabilized
power source)
(NOTE 1) Device number 0 is set.
J30
(2)When multiple power Mates share one CRT/MDI Max.16 Power
Mates
Power Mate
JD41 JD13
#0
(NOTE1)
CRT/MDI
CPD1
J30
JN1 FG
24V DC power
source 1.0A
(NOTE 1) If the same device number is used for
two or more units, the information is
not correctly shown on the CRT/MDI
unit.
(NOTE 2) Each Power Mate needs one display
link adapter. Terminating unit must be
connect to the last display link adapter.
(NOTE 3) When two or more Power Mates share
one CRT/MDI unit, specify the number
of Power Mates connected to the unit
in parameter No. 3170 Maximum axes
displayed on the common use screen
are 18 axes.
(NOTE 4) To identify each Power Mate, a name
can be given to it. See parameters
No. 3141 to No. 3146.
Power Mate
JD41
#1
(NOTE1)
Power Mate
JD41
#2
(NOTE1)
Power Mate
JD41
#n
(NOTE1)
Device number
selection switch
#1...
#0 #15
Common
J47
JD41B
J45
JD41
JD41B
JD41
J45
J45
JD41A
JD41B
JD41
J45
JD41A
J45
JD41B
JD41
J45
J45
JD41A
J45 or J142
Display
link termi-
nating unit
(NOTE2)
(NOTE2)
(NOTE2)
(NOTE2)
JD41A
NOTE
When a CRT link is used, all the Power Mates must be
turned on. If any one Power Mate is not turned on,
disconnect it from the display link using JD41 of the Power
Mate or the display link adaptor.