B–63173EN/03
10. CONNECTION TO PERIPHERALS
411
3) Details of cable J179
JD41 on display link adapter
(PCR–EV20MDT)
1 (RXD) 11 0V
2 (*RXD) 12 0V
3 (TXD) 13
4 (*TXD) 14
5 RXALM 15
6 *RXALM 16
7 TXALM 17 COMMA
8 *TXALM 18 *COMMA
919
10 20
J179
JD41
RXALM
*RXALM
TXALM
*TXALM
0V
0V
COMMA
*COMMA
Connector panel
RXALM
*RXALM
TXALM
*TXALM
0V
0V
COMMA
*COMMA
Connector panel
Cable connection (J179)
Shield
Recommended cable: A66L–0001–0284#10P (#28AWG 10 pairs, common shield) <Hitachi Cable, Ltd., Oki Electric Cable Co., Ltd.>
Recommended connector on the cable side: PCR–E20FS or PCRE20FA, housing: PCR–V20LA <Honda Tsushin>
NOTE
1 Make no connection to a pin with no name indicated or its name parenthesized in connector
JD41.
2 Do not change the combination of the wires of twisted pairs.
3 When the connector panel and display link adapter are installed very close to each other, and
there is no noise around these units, the shield of the cable need not be clamped. (The cable
is not necessarily a shielded cable.)
4 The cable length of cable J179 should be as short as possible. The total length of cables J179
and J180 is 500 mm maximum.